Installation instructions, Location of your washer, Rough-in dimensions – GE Front Load Washer WHDVH626 User Manual

Page 13: Do not install the washer, Minimum installation clearances

Advertising
background image

13

Installation Instructions

LOCATION OF YOUR WASHER

Do Not Install the Washer:

1.

In an area exposed to dripping water or outside
weather conditions. The ambient temperature
should never be below 60°F (15.6°C) for proper
washer operation.

2.

In an area where it will come in contact with curtains
or drapes.

3.

On carpet. The floor MUST be a hard surface with
a maximum slope of 1/2

″ per foot (1.27 cm per

30 cm). To make sure the washer does not vibrate
or move, you may have to reinforce the floor.

NOTE:

If floor is in poor condition, use 3/4

impregnated plywood sheet solidly attached to existing
floor covering.

IMPORTANT:

Minimum Installation Clearances

When installed in alcove: Sides, Rear,

Top = 0

″ (0 cm)

When installed in closet: Sides, Rear,

Top = 0

″ (0 cm), Front = 1″ (2.54 cm)

Closet door ventilation openings required:

2 louvers each 60 square in. (387 cm

2

), located 3

(7.6 cm) from top and bottom of door

ROUGH-IN DIMENSIONS

SIDE

FRONT

27.0”

(68.6 cm)

20.4” (51.9 cm)

ELECTRONIC TRANSPARENT VISOR

2.2”

(5.6 cm)

40.6”*

(103.1 cm)

30.6”

(77.7 cm)

1.6”

(3.9 cm)

40.6”*

(103.1cm)

39.1”

(99.2 cm)

*NOTE: With pedestal, 52.6”.