G0460/G0461 12" Sliding Table Saw

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the setup pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

Full Load Amperage Draw

G0460 5 HP 220V 1-Phase ...................22 Amps
G0461 7.5 HP 220V 3-Phase ................20 Amps
G0461 7.5 HP 440V 3-Phase ................ 10 Amps

Circuit Requirements

We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri-
cian to ensure compliance with wiring codes.

If

you are unsure about the wiring codes in your

area or you plan to connect your machine to a

shared circuit, consult a qualified electrician.

G0460 220V 1-Phase ..............................30 Amp
G0461 220V 3-Phase ..............................30 Amp
G0461 440V 3-Phase ..............................15 Amp

Minimum Cord Requirements

For 220V connection, we recommend using a
stranded-copper flexible cord that meets the
minimum criteria listed below, does not exceed
50 ft., and has an insulation type that starts with
"S." The exact insulation type should account for
any exposure to moisture, heat, and oils in the
working environment.

G0460 220V 1-Phase ...........10/3 AWG, 300VAC
G0461 220V 3-Phase ...........10/4 AWG, 300VAC
G0461 440V 3-Phase ...... Electrician to Hardwire

SECTION 2: CIRCUIT REQUIREMENTS

Figure 4. NEMA L6-30 plug and receptacle.

220V Plug/Connection Type

G0460 220V 1-Phase .................................L6-30
G0461 220V 3-Phase ............................... L15-30

Figure 5. NEMA L15-30 plug and receptacle.

�������

��

�������

�������

��

������������

Figure 6. Hardwired locking disconnect switch.

G0461 440V Connection to Power

Have a qualified electrician hardwire this machine
to a dedicated locking shut-off switch that is con-
nected to the main power source.