Installation Instructions

5

7

EXHAUST CONNECTION

THIS DRYER COMES READY FOR REAR

EXHAUSTING. IF SPACE IS LIMITED, USE

THE INSTRUCTIONS IN SECTION 9 TO

EXHAUST DIRECTLY FROM THE SIDES OR

BOTTOM OF THE CABINET.

RECOMMENDED

CONFIGURATION

TO MINIMIZE

EXHAUST

BLOCKAGE.

ELBOW HIGHLY

RECOMMENDED

ELBOW HIGHLY

RECOMMENDED

NOTE:

ELBOWS WILL PREVENT DUCT

KINKING AND COLLAPSING.

STANDARD REAR EXHAUST

(Vented above floor level)

WARNING -

TO REDUCE THE

RISK OF FIRE OR PERSONAL INJURY:

• This clothes dryer must be exhausted to the outdoors.

• Use only 4” rigid metal ducting for the home exhaust

duct.

• Use only 4” rigid metal or UL-listed flexible metal

(semi-rigid or foil-type) duct to connect the dryer

to the home exhaust duct. It must be installed

in accordance with the instructions found in

“Connecting The Dryer To House Vent” on page 6 of

this manual.

•Do not terminate exhaust in a chimney, a wall,

a ceiling, gas vent, crawl space, attic, under an

enclosed floor, or in any other concealed space of

a building. The accumulated lint could create a fire

hazard.

• Never terminate the exhaust into a common duct

with a kitchen exhaust system. A combination of

grease and lint creates a potential fire hazard.

• Do not use duct longer than specified in the exhaust

length table. Longer ducts can accumulate lint,

creating a potential fire hazard.

•Never install a screen in or over the exhaust duct. This

will cause lint to accumulate, creating a potential fire

hazard.

• Do not assemble ductwork with any fasteners

that extend into the duct. These fasteners can

accumulate lint, creating a potential fire hazard.

• Do not obstruct incoming or exhausted air.

• Provide an access for inspection and cleaning of

the exhaust system, especially at turns and joints.

Exhaust system shall be inspected and cleaned at

least once year.

GAS

INLET

PIPE

EXTERNAL

DUCT

OPENING

DUCT TAPE OR

DUCT CLAMP

DUCT TAPE OR

DUCT CLAMP

(CUT TO PROPER

LENGTH)

4" METAL DUCT

CSA (AGA) APPROVED

NEW FLEXIBLE GAS

LINE CONNECTOR

NOTE:

WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.

HOWEVER, IF FLEXIBLE DUCTING IS USED IT MUST BE UL-LISTED METAL

NOT PLASTIC.

FOR STRAIGHT LINE INSTALLATION, CONNECT THE DRYER EXHAUST TO

THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP.

STANDARD REAR EXHAUST

(Vented at floor level)

8

LEVELING DRYER

LEVEL

SIDE-TO-SIDE.

4 LEVELING LEGS

2 ANTI-TIP LEGS

LEVEL

FRONT-TO-BACK.

STAND THE DRYER UPRIGHT NEAR THE

FINAL LOCATION AND ADJUST THE 4 LEVELING

LEGS TO MATCH THE HEIGHT OF YOUR WASHER.

ADJUST THE 2 ANTI-TIP LEGS TO CONTACT

THE FLOOR.