G7947/G7948 12 Speed Floor Drill Press

Serious personal injury could occur if you

connect the machine to the power source

before you have completed the set up pro-

cess. DO NOT connect the machine to the

power source until instructed to do so.

110/220V Operation

SECTION 2: CIRCUIT REQUIREMENTS

Amperage Draw

The Model G7947/G7948 motor is prewired to
110V, but can be rewired to 220V. The machine
draws the following amps under load:

G7947 at 110V ....................................... 10 Amps
G7947 at 220V .........................................5 Amps

G7948 at 110V ....................................... 15 Amps
G7948 at 220V ..................................... 7.5 Amps

Circuit Requirements

Only connect your machine to a circuit that meets
the requirements below. Always check to see if
the wires and circuit breaker in your circuit are
capable of handling the amperage draw from
your machine, as well as any other machines that
could be operating on the same circuit. If you are
unsure, consult a qualified electrician.

G7947 110V Minimum Circuit ..................15 Amp
G7947 220V Minimum Circuit ..................10 Amp

G7948 110V Minimum Circuit ..................20 Amp
G7948 220V Minimum Circuit .................10 Amp

Figure 3. 6-15 plug and outlet.

NOTICE

The Model G7947/G7948 is prewired for

110V operation. For 220V operation, you

must rewire your motor. A qualified elec-

trician must inspect any rewiring to this

machine before putting it into operation.

Plug Type

The Model G7947/G7948 comes prewired with a
NEMA 5-15 plug. If you wish to rewire the motor
to 220V we recommend using the following plug
(see

Figure 3 for an example):

220V Plug & Receptacle ................ 6-15 or L6-15