7.14 Working from the outer edges, place the second

row of pebbles against the rear of the first row. Note the

orientation of each pebble, as this is important to the

performance of the fire. See diagram 14.

14

AR1172

7.15 Place the rear row of pebbles on top of the flame baffle,

these must touch the rear panel. See diagram 15.

15

AR1173

7.16 Place the remaining five pebbles between the second and

rear rows. See diagram 16.

16

AR1174

6

5

4

5

2

8. OXYGEN DEPlETION SENSOR

8.1 The appliance is fitted with an oxygen sensitive pilot system

which acts to cut off the gas supply to the fire should the

oxygen in the room fall below its normal level. If the fire is

turned off by this device, it usually indicates that there is a

problem with the flue system, and this should be inspected

by a qualified engineer. Do not attempt to use the fire

until an engineer says it is safe to do so.

This device is not a substitute for an independently

mounted carbon monoxide detector.

9. FlAME FAIlURE DEvICE

9.1 This is a safety feature incorporated in all GAZCO fires

which automatically switches off the gas supply if the pilot

light goes out and fails to heat the thermocouple.

10. ‘RUNNING IN’

10.1 The surface coating on the coals used in your GAZCO fire

will ‘burn off’ during the first few hours of use, producing a

harmless and temporary odour. This will disappear after a

short period of use. If the odour persists, ask your installer

for advice.

11. SERvICING

11.1 This fire must be serviced every 12 months by a qualified

Gas Engineer. In all correspondence, always quote the

appliance type and serial number, which may be found on

the data badge located on a chain beneath the control valve.

12. vENTIlATION

12.1 Any purpose provided ventilation should be checked

periodically to ensure that it is free from obstruction.

13. INSTAllATION DETAIlS

13.1 To assist in any future correspondence, your installer should

have completed this commissioning sheet, this records, the

essential installation details of the appliance. In all

correspondence always quote the Model Number and

Serial Number.

USER INSTRUCTIONS