GAS AND ELECTRICAL LOCATION

The position of the electrical supply receptacle and
the gas supply pipe entering the cabinet should be
positioned as shown in the shaded areas marked below.
The cooktop is equipped with a 4 ft (1.2 m) power
cord, which should reach any desired location on the
cabinet walls. The cooktop must be disconnected from
the power supply before any servicing is carried out.

PREPARING THE COUNTERTOP

Cut out the opening as shown in the diagram.
Measure carefully when cutting the countertop,
making sure the sides of the opening are parallel
and the front and rear cuts are exactly
perpendicular to the sides.

The front of the opening must clear the front
support rail on the cabinet, and the rear of the
opening must clear the rear support of the cabinet.

Chamfer all exposed edges of decorative laminate
to prevent damage from chipping.

Radius corners of cutout and file to ensure smooth
edges and prevent corner cracking.

Rough edges inside corners which have not been
rounded and forced fit can contribute to cracking
of the countertop laminate.

Countertop must be supported within 3

″ (7.6 cm)

of cutout.

Installation Instructions

PROVIDE ADEQUATE
GAS SUPPLY

This cooktop is designed to operate on natural gas
only at 5

″ (12.7 cm) of water column pressure or

on LP gas at 10

″ (25.4 cm) of water column

pressure. It is shipped from the factory set for
natural gas. If you decide to use this cooktop with
LP gas, conversion adjustments must be made by a
service technician or other qualified person.

A pressure regulator is to be connected in series
with the manifold of the cooktop and must
remain in series with the supply line, regardless
of whether natural or LP gas is being used.

For proper operation, the maximum inlet
pressure to the regulator must be no more than
10

″ (25.4 cm) water column pressure for natural

gas, or 14

″ (35.5 cm) water column pressure for

LP gas. For checking the regulator, the inlet
pressure must be at least 1

″ (2.5 cm) greater than

the regulator output setting. If the regulator is set
for 5

″ (12.7 cm) of water column pressure, the

inlet pressure must be at least 6

″ (15.2 cm).

For ease of installation, and if local codes permit,
the gas supply line into the cooktop should be
1/2

″ (13 mm) or 3/4″ (19 mm) I.D. flexible

metal appliance connector three (0.9 m) to five
feet (1.5 m) in length.

Not less than 1

7

8

(4.8 cm)

Not less than

15

16

″ (2.4 cm)

8

13

16

″ min. cut-out

to wall (22.2 cm)

8

13

16

″ min. cut-out

to wall (22.2 cm)

Countertop cut-out dimensions

Back of Counter

Front of Counter

PRESSURE TESTING

The maximum gas supply pressure for the
regulator supplied on this appliance is 14

(35.5 cm) W.C. The test pressure for checking
this regulator must be at least 6

″ (15.2 cm)

W.C. for natural gas, and at least 11

″ (27.9 cm)

W.C. for LP. It is shipped from the factory set
for natural gas at 5

″ (12.7 cm) W.C.

This appliance and its individual shut-off valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at test pressures in excess of

1

2

PSIG.

This appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than

1

2

PSIG.

21

″ ±

1

16

53.5 ± 0.16 cm

29

″ ±

1

16

73.66 cm ± 0.16 cm

2

3

4

5

Gas pipe
location

Electrical outlet
12

″ (30.5 cm)

above cabinet
floor (mount on
side or back
cabinet wall 3

[7.6 cm] min.
from centerline)

3

″ (7.6 cm) Min.

4

″ (10.2 cm) (to clear toe kick area)

22

PREPARATION