31

LP Conversion Instructions

With the installation of this conversion kit, the

cooktop should operate on LP gas at 10

″ of water

column pressure.

The pressure regulator must be connected in series

with the manifold of the cooktop and must remain
in series with the supply line. For proper operation,
the maximum inlet pressure to the regulator must
be no more than 14

″ water column pressure for

LP gas.

When checking the regulator, the inlet pressure

must be at least 1

″ greater than the regulator

output setting. If the regulator is set for 10

″ of

water column pressure, the inlet pressure must
be at least 11.

IMPORTANT –

Disconnect the cooktop

and the individual shut-off valve from the gas supply
piping system during any pressure testing of that system
at test pressures greater than 1/2 psig. Isolate the
cooktop from the gas supply piping system by closing
the individual manual shut-off valve to the cooktop
during any pressure testing of the gas supply piping
system at test pressures equal to or greater than 1/2 psig.

GAS SUPPLY

BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY
AT THE SHUT-OFF VALVE. DISCONNECT THE
ELECTRICAL SUPPLY FROM THE COOKTOP.

TURN OFF GAS AND
ELECTRIC SUPPLY

CONVERT THE
PRESSURE REGULATOR

Locate the pressure regulator under the front of
the cooktop.

A

1

Remove the nut from the pressure regulator with
an adjustable wrench.

B

Remove the plastic pin from the inside of the nut,
turn the pin 180° and snap the pin back into the nut.

C

Re-install the nut onto the regulator.
Apply the LP Conversion label next to the
Rating Plate.

E

D

Shut-off valve

Electrical supply

Nut

Natural gas

LP gas

Nut

Natural gas

LP gas