MDS Mercury Series Startup Guide

05-4558A01, Rev. C

Step 3—Measure & Connect Primary Power

The DC input power to the transceiver must be within 10–30 Vdc and
capable of continuously providing at least 2.5 Amperes. A power con-
nector with screw-terminals is provided with each unit. Strip the wire
leads to 6 mm (1/4 inch). Be sure to observe proper polarity as shown
in

Figure 2

with the positive lead (

+

) on the left side; negative on the

right side.

Invisible

place

holder

Figure 2. Power Connector

(Polarity: Left +, Right –)

The transceiver must be used with negative-ground sys-
tems only. The power supply should be equipped with
overload protection (NEC Class 2 rating), to protect
against a short circuit between its output terminals and
the radio’s power connector.

NOTE:

Typically, it takes about 30 seconds for the transceiver to fully
power up, and may take several minutes to associate with
another unit, especially if GPS is required for time synchroni-
zation.

Step 4—Review the Transceiver’s Configuration

There are two key settings that must be known before placing the unit
into service:

Network Name

Common identifier used by all of the units, that

are part of the same network. The Network Name must be pro-
grammed to enable Remote units to associate with the Access
Point unit. (Default name is

MDS-Mercury

.)

IP Address

—Must be a unique address to allow for IP access

through the

LAN

port or over-the-air. (Default is

192.168.1.1

)

CAUTION

POSSIBLE

EQUIPMENT

DAMAGE