Advance Planning

The warming drawer may be installed directly
into a wall or wall oven cabinetry.

The warming drawer may be installed below
a countertop, a single or double oven and
side by side using 2 drawers.

When installing warming drawer with a
cooktop allow a 2

″ minimum from bottom

of a cooktop burner box to top of cutout.

Electrical power cord is located on the right
side of the warming drawer. Locate the outlet
within reach of the 56

″ long power cord in

adjacent cabinet, within 42

″ of the right side

or 16

″ from the left side of the cutout.

A recessed receptacle can be installed on
the right side of the cutout, 7

″ maximum

from the back of the cabinet.

Grounding the Appliance

IMPORTANT—(Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.

Do not use an extension cord or adapter plug
with this appliance. Follow National Electrical
codes and ordinances.

This warming drawer must be supplied with 120V,
60Hz, and connected to an individual, properly
grounded branch circuit, and protected by a 15
or 20 amp circuit breaker or time delay fuse.

A properly grounded 3-prong receptacle
should be located within reach of the drawer’s
56

″ long power cord.

Locate the receptacle in an adjacent cabinet.

—within 42

″ of the right side or,

—within 16

″ of the left side or

—A recessed receptacle may be located on the

right side of the cutout, 7

″ maximum from

the back of the cabinet. In this location, the
excess power cord should be coiled and
taped to the right side of the unit.

IMPORTANT—(Please read carefully)

The power cord of this appliance is equipped
with a 3-prong (grounding) plug that mates with
a standard 3-prong grounding wall receptacle to
minimize the possibility of electric shock. The
customer should have the wall receptacle and
circuit checked by a qualified electrician to make
sure the receptacle is properly grounded and has
the correct polarity.

Where a standard 2-prong wall receptacle is
encountered, it is the personal responsibility
and obligation of the customer to have it
replaced with a properly grounded 3-prong
wall receptacle.

Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.

DO NOT USE AN EXTENSION CORD.

Recessed receptacle
7

″ max. from rear

on right side

Drill 1

1

2

″ hole for

power cord for left
or right side outlet
location