Installation instructions, Power cord and strain relief installation – GE Electric Coil & Radiant JBP22 User Manual

Page 37

Advertising
background image

37

Installation Instructions

POWER CORD AND STRAIN
RELIEF INSTALLATION

Remove the wire cover (on the lower
back of the range) by removing two (2)
screws using a 1/4” nut driver.
Do not discard these screws.

Remove the knockout ring (1

3

8

″) located

on bracket directly below the terminal
block. To remove the knockout, use a
pair of pliers to bend the knockout ring
away from the bracket and twist until
ring is removed.

B

A

3

For power cord installations only (see
the next step if using conduit), assemble
the strain relief in the hole. Insert the
power cord through the strain relief and
tighten. Allow enough slack to easily
attach the cord terminals to the terminal
block. If tabs are present at the end of
the winged strain relief, they can be
removed for better fit.

NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket should be installed before
reinstalling the rear range wiring cover.

Skip to Step 4 or 5.

C

Wire cover

2 screws
to remove
wire cover

Knockout ring
in bracket

Knockout
ring removed

Power cord

Strain relief

Terminal
block

Bracket

Retaining
tab

Back of range

Terminal block
(appearance
may vary)

For conduit installations only, purchase a
squeeze connector matching the diameter
of your conduit and assemble it in the hole.
Insert the conduit through the squeeze
connector and tighten. Allow enough slack to
easily attach the wires to the terminal block.

NOTE: Do not install the conduit without a
squeeze connector. The squeeze connector
should be installed before reinstalling the
rear range wiring cover.

Skip to Step 6 or 7.

D

Squeeze

connector

Terminal
block

Conduit

Bracket

Advertising