Troubleshooting – Grizzly Air Palm Nailer H6141 User Manual

Page 12

Advertising
background image

h6141 air palm nailer

-12

-

troubleshooting

symptom

possible cause

possible solution

air leaking between
housing and hose.

1. loose screws in housing.
2. Damaged o-ring.
3. loose air fitting.

1. tighten screws.
2. replace o-ring.
3. tighten air fitting and use

teflon tape.

air leaking between
housing and cap
assembly.

1. Damaged gasket.

1. replace damaged gasket.

tool skips on nail head
while discharging.

1. air leaks.
2. Dirt in cylinder.
3. inadequate air flow to

tool.

4. Worn o-ring on piston or

lack of lubrication.

5. gasket leaking.

1. tighten screws and fittings.
2. Clean cylinder and housing.
3. Check fitting, hose, compres-

sor and air pressure.

4. replace

piston

o-ring.

lubricate.

5. replace gasket.

tool drives nails too
far; depth guide is
loose.

1. Broken spring.
2. loose nose piece.

1. replace spring.
2. tighten nose piece and use

teflon tape.

nailer does not fire.

1. piston shaft damaged.
2. air pressure too low.

1. replace piston shaft.
2. Check/increase air pressure.

Advertising