Fig. 4

06443

05151A

DD

31

26

43

1

20

45

Selecting a Fluid Nozzle and Air Cap

WARNING

PRESSURIZED EQUIPMENT HAZARD
To reduce the risk of an injury, follow the Pressure
Relief Procedure
on page 11 before removing or
installing a fluid nozzle and/or air cap.

The gun is supplied with a 0.059 in. (1.5 mm) fluid
nozzle, P/N 185158, and air cap, P/N 193033. If your
application requires a different nozzle and air cap
combination, use instruction manual 307803 or consult
your authorized Graco distributor to select the ap-
propriate fluid nozzle and air cap. Install the air cap
and fluid nozzle into the gun barrel as instructed in Air
Cap/Nozzle/Resistor Stud Replacement
, page 22.

Operating the Spray Gun

WARNING

PRESSURIZED EQUIPMENT HAZARD
To reduce the risk of an injury, follow the Pressure
Relief Procedure
on page 11 whenever you stop
spraying and whenever you are instructed to
relieve pressure.

WARNING

COMPONENT RUPTURE HAZARD
To reduce the risk of component rupture,
which can cause serious injury, do not
exceed the maximum working pressure

of the lowest rated system component. This equip-
ment has a 100 psi (7 bar, 0.7 MPa) maximum
working air and fluid pressure.

Follow the steps on page 13 to establish the correct
fluid flow and air flow. Do not turn the ES ON-OFF
lever to ON yet.

Advertising