200 • schematics and hose drawings, Electrical schematic – Genie 106730 User Manual

Page 16

Advertising
background image

1

2

3

4

5

6

7

8

N

M

L

K

J

I

H

G

F

E

D

C

B

A

Part No. 106730

Welder Supplement

Electrical Schematic

July 2004

200 • Schematics and Hose Drawings

DRIVE

EDC

REVERSE

DRIVE

EDC

REVERSE

DRIVE

EDC

FOR

W

ARD

DRIVE

EDC

FOR

W

ARD

B

C

U4

A

D

C5-21

C5-20

C1B-5

C1B-4

C31EDC

WH/BK

C31EDC

WH/BK

C30EDC

WH

C30EDC

WH

C1P-5

C1P-4

C45GEN

GR/WH

C45GEN

GR/WH

TB45

TS47

P25FS-RD

P24FS-WH

TS4

TB35

C35RPM

BK/RD

C35RPM

BK/RD

C1B-9

C1P-9

RPM

HI

RPM

HI

GENERA

TO
R

O

N

GENERA

TO

R

ON

D12

RPM

LO

RPM

LO

FOOTSWITCH

TB31

TB30

2

4

6

8

1

3

5

7

RS232RxD

A1 BATTERY +

A1 BATTERY +
A2 SENSOR POWER +5 VDC

A2 SENSOR POWER +5 VDC
A3 BATTERY-

A3 BATTERY-

B1 VALVE 0 FWD COIL

B1 VALVE 0 FWD COIL
B2 VALVE 1 NC

B2 VALVE 1 NC
B3 DIGITAL OUTPUT BYPASS/OMRON

B3 DIGITAL OUTPUT BYPASS/OMRON

C1 TxD

C1 TxD
C2 RxD

C2 RxD
C3 /BOOT

C3 /BOOT

D1 ANALOG 0 JOYSTICK

D1 ANALOG 0 JOYSTICK
D2 ANALOG 1 NC

D2 ANALOG 1 NC
D3 DIG IN 3 NC

D3 DIG IN 3 NC

E1 NOT USED

E1 NOT USED
E2 NOT USED

E2 NOT USED
E3 NOT USED

E3 NOT USED

F1 DIG IN 0

F1 DIG IN 0
F2 DIG IN 1 GENERATOR ON

F2 DIG IN 1 GENERATOR ON
F3 DIG IN 2

F3 DIG IN 2

RS232TxD

RS232TxD

CR4

HIGH

IDLE

HIGH

IDLE

RELA

Y

C45GEN

GR/WH

C45GEN

GR/WH

V151HG GN

V151HG GN

V150HG GN/BK

V150HG GN/BK

1k ohms

1k ohms

124 ohms

124 ohms

124 ohms

124 ohms

Adjustments

1. Connect a digital multimeter

1. Connect a digital multimeter
(DMM) with a frequency counter to

(DMM) with a frequency counter to
the 110 vac outlet. Adjust the

the 110 vac outlet. Adjust the

potentiometer until a frequency of

potentiometer until a frequency of

66.5 HZ is obtained with no load

66.5 HZ is obtained with no load
on the generator.

on the generator.

A
B
C

P26FS-BK

TB29

2

1

3

C1B-3

C1P-3

C29MS

RD/WH

C29MS

RD/WH

BYP
ASS

VA

LV

E

MOT

OR
STROKE

MOT

OR
STROKE

VA

LV

E

SX Controller

SX Controller

RELAY

8 N.C.

8 N.C.

2 COM

2 COM

1 N.O.

1 N.O.

3 GND

3 GND

5 SW INPUT

5 SW INPUT

TIME DELAY

TIME DELAY
MODULE 4S

MODULE 4S

Modification note

Modification note

Replace two position terminal strip #45 and use 74911

Replace two position terminal strip #45 and use 74911

four position terminal strip in its place. Use the

four position terminal strip in its place. Use the

name plate from the old two position terminal.

name plate from the old two position terminal.

Add three Genie P/N 45762 6 amp 200 PIV diodes in

Add three Genie P/N 45762 6 amp 200 PIV diodes in

the position shown in the schematic.

the position shown in the schematic.

Theory of Operation

Theory of Operation

1. Turning on the Generator supplies current to the high idle relay

1. Turning on the Generator supplies current to the high idle relay
through the diode switching the engine to high RPM. In addition

through the diode switching the engine to high RPM. In addition
the diode between TB45 and TB29 supplies power to the motor

the diode between TB45 and TB29 supplies power to the motor

stroke valve switching the motors to high speed/low torque mode.

stroke valve switching the motors to high speed/low torque mode.

2. The SX controller is turned ON supplying power to bypass valve

2. The SX controller is turned ON supplying power to bypass valve
and the change over relay. The EDC valve is switched over to

and the change over relay. The EDC valve is switched over to
the output of the SX controller.

the output of the SX controller.

3. When the AC generator is turned OFF the SX module will ramp

3. When the AC generator is turned OFF the SX module will ramp
the output to the EDC to threshold preventing cavitation to the

the output to the EDC to threshold preventing cavitation to the

hydraulic motor powering the generator. When threshold is

hydraulic motor powering the generator. When threshold is
reached the bypass valve is turned OFF.

reached the bypass valve is turned OFF.

4. The time delay module keeps the SX controller ON for four

4. The time delay module keeps the SX controller ON for four
additional seconds after the ESTOP is pressed allowing for a

additional seconds after the ESTOP is pressed allowing for a
controlled ramp down of the generator.

controlled ramp down of the generator.

TO TB#24

TO TB#24

TO TB#23

TO TB#23

PLATFORM

GROUND

CR46

16

15

ALC-500

20

C2P-7

C2B-7