2-Wire Power Cord Installation

WARNING:

THE POWER LEADS

MUST BE CONNECTED TO THE OUTSIDE (BRASS
COLORED) TERMINALS. THE GROUND (EARTH)
LEAD MUST BE CONNECTED TO THE FRAME OF
THE RANGE WITH THE GREEN GROUNDING
SCREW.

RANGE FRAME MUST BE GROUNDED PROPERLY
TO AVOID POTENTIAL ELECTRICAL SHOCK.

Remove the 2 screws from the connector block.
Remove the grounding screw and strap from

the connector block middle location and the

screw connecting it to the frame of the range.

Insert screws through each power cord

terminal ring and into connector block until

screw engages nut. Tighten screws securely.

Attach ground (earth) wire to the frame of the

range. This is the green, or green with yellow

stripe, wire.

After

Before

Green screw grounds
range to earth (ground)

Green grounding screw and
plate (grounding to range)

Red “L” (Line)

Black “N” (Neutral)

2-Wire Conduit Installation

WARNING:

CONNECTOR BLOCK IS

APPROVED FOR COPPER WIRE CONNECTION
ONLY. IF ALUMINUM WIRE IS USED, SEE NOTE
BELOW.

Remove the 2 screws from the connector block.

Remove the grounding strap from the connector

block middle location and the screw connecting it to

the frame of the range. Insert bare wires between

the connector block terminals and movable nuts.

Tighten screws securely. Attach ground (earth) wire

to the frame of the range.

NOTE: ALUMINUM WIRING

Do not connect aluminum wire to connector

block. Use copper building wire rated for the

correct amperage and voltage to make 3

(three) 7.62 cm (3-inch) copper jumper wires.

Connect wire as described above.
Splice copper wires to aluminum wiring using

special connector terminals designed for

joining copper to aluminum and follow the

connector manufacturer’s recommended

procedure closely.

Wire used, location and enclosure of splices, etc., must
conform to good wiring practices and local codes.