Pressure control repair – Graco 190ES 309063F User Manual

Page 22

Advertising
background image

22

309063

Pressure Control Repair

For these models and series only:

232900 F

232901 E

233797 E

233815 E

Motor Control Board

Removal

1.

Relieve pressure; page 6.

2. Remove 4 screws (17) and control cover (16).

3. Disconnect motor connector, pressure control

connector white wire to control board (8) and black

wire to switch (4).

4. Remove 4 screws (9) and control board (8).

Installation

1. Assemble control board (8) with 4 screws (9).

2. Connect motor connector, pressure control con-

nector white wire to control board (8) and black

wire to switch (4).

3. Install cover (16) with 4 screws (17).

Fig.

15

15

14

13

12

11

10

6

5

4

1

3

9

2

18

17

8

16

2

19

7

ti7414a

14a

Advertising