309063

Motor Replacement

Disassembly

1.

Relieve pressure; page 6.

2. Remove pump; Displacement Pump Replace-

ment, page 26.

CAUTION

Do not drop gear cluster (7) when removing drive

housing (10). Gear cluster may stay engaged in

motor front end bell or drive housing.

3. Remove drive housing; Drive Housing Replace-

ment, page 24.

4. Remove fluid manifold; Pressure Control Re-

placement, page 23.

5. Remove control board; Control Board Replace-

ment, page 20 or 22.

6. Remove strain relief (37; Fig. 10, 13 or 14) and

motor fan (2).

7. Remove three screws (22) behind board and

remove control housing (21).

8. Remove four screws (22) and motor (1) from

frame (63).

Assembly

1. Install new motor (1) on frame (63) with four

screws (22).

2. Install control housing (21) with three screws (22).

3. Install strain relief (37; Fig. 10, 13 or 14) and motor

fan (2).

4. Install fluid manifold; Pressure Control Replace-

ment, page 23.

5. Install control board; Control Board Replace-

ment, page 20 or 22.

6. Install drive housing (10); Drive Housing Re-

placement, page 24.

7. Install pump (13); Displacement Pump Replace-

ment, page 26.

ti0054b

Fig. 17

22

1

1

Liberally apply grease

39

1

18

36

35

22

1

63

21

Advertising