Operating instructions – Stovax 7063 User Manual

Page 6

Advertising
background image

6

OPERATING INSTRUCTIONS

.1 When new, it is best to burn the fire at a low output for

the first few days of use. This will allow the construction to

settle and all fixing glues and paint to fully cure.

. Avoid touching the paint during the first period of use.

. During this time the stove may give off some unpleasant

odours, and we recommend that you keep the room well

ventilated during this period to avoid a build-up of fumes.

.1 Open the Airwash control fully and open the Primary air

control,

(multifuel versions only) to approximately 25% open.

. Place some pieces of firelighter or dry crumpled paper on

the grate and cover with some small pieces of dry kindling

wood. Light the paper or firelighters.

. To avoid the build-up of condensation on the door glass

it is advisable to leave the door slightly open as the fire

establishes, and the glass warms.

. As the fire becomes established add a few larger pieces

of wood and fully close the door. Do not initially add too

many logs as this may smother the fire. do not leave the

stove with the door open as this could over-fire the stove

and cause permanent damage

.

.5 As the fire becomes established close the Primary air

control

(multifuel versions only) and control the burn rate

using the Airwash control only.

.6 To burn wood efficiently it is best to allow a bed of ash to

build-up on the grate, or the base of the stove, and control

the combustion using the Airwash control only.

.7 Before re-fuelling the stove it is advisable to first rake the

embers evenly over the firebed then open the Airwash

control

fully for a few minutes, to establish a glowing bed

before adding new logs.

.8 Allow the new logs to burn at high output for a few minutes

before adjusting the burn rate with the Airwash control,

to the desired setting. It is best to refuel little and often to

maintain clean and efficient burning.

.9 The ideal control settings to suit the particular installation

and personal preferences will be established by experience

in using the stove.

.10 Do not load fuel higher than the log guard at the front of

the stove and the secondary combustion air inlet holes at

the back of the firebox. It is not recommended to load large

amounts of logs and burn with the Airwash control on

low settings for long periods of time. This will reduce the

effectiveness of the glass cleaning effect of the airwash and

will cause a large build-up of tars and creosotes in the stove

and flue system.

.11 We would recommend that the stove be burnt at high

output for at least 0 minutes each day when it is in use.

This will help reduce the build-up of tars and creosotes

within the stove and flue system.

.1 do not burn construction timber, painted, impregnated /

treated wood or manufactured board products

.

.1 Open the Airwash control to approximately 50% and

Primary air control

fully.

. Place some pieces of firelighter or dry crumpled paper on

the grate and cover with some small pieces of dry kindling

wood. Light the paper or firelighters.

. To avoid the build-up of condensation on the door glass

it is advisable to leave the door slightly open as the fire

establishes, and the glass warms.

. As the fire becomes established add pieces of solid fuel and

fully close the door. Do not initially add too much fuel as

this may smother the fire. do not leave the stove with the

door open as this could over-fire the stove and cause

permanent damage

.

.5 As the fire becomes established reduce the Airwash air

control

to approximately 5% and control the burn rate

using the Primary air control only.

.6 To burn solid fuel efficiently it is best to control the

combustion using the Primary air control only.

.7 Before re-fuelling the stove it is advisable to de-ash the

firebed, using the riddling grate system. This is completed as

follows:-

Huntingdon 25 / 28

Using the tool provided pull and push the riddling control.

This will cause the centre grate section to rotate and ash to

fall into the ashpan below.

Huntingdon 30/35 multifuel /40 multifuel

Place the tool provided onto the square end of the riddling

control rod. Then, by pushing and pulling the handle de-ash

the firebed. Moving the handle will cause the grate bars to

move back and forth, with the ash falling into the ashpan

below. do not use bare hands to operate the riddling

system

.

.8 Open the Primary air control fully for a few minutes, to

establish a glowing bed before adding new fuel. Allow the

new fuel to burn at high output for a few minutes before

adjusting the burn rate with the Primary air control to the

desired setting. It is best to refuel little and often to maintain

clean and efficient burning.

3. BURNING WOOd

(Wood and multi-fuel stoves)

4. BURNING SOlId FUEl

(Multi-fuel stoves only)

2. USING THE STOVE FOR THE FIRST TIME

Advertising
This manual is related to the following products: