Operating instructions, Burning performance – Stovax 7063 User Manual

Page 8

Advertising
background image

8

OPERATING INSTRUCTIONS

A number of factors can affect the performance of the

Huntingdon stove. Some of these are listed.

10.1 Fuel Quality (Wood)

Use only seasoned wood with a moisture content of

less than 0%. Well seasoned logs should have the bark

beginning to lift and peel away, along with deep cracks

radiating from the centre of the log. Logs should feel lighter

than fresh cut wood of a similar size and sound hollow

when struck against each other. Logs should not feel damp

to the touch, have any visible moisture oozing from them or

moss and fungal growths on them.

Symptoms of poor performance related to wet woods

include:

• Difficulty getting a fire going and keeping it burning well,

• Smoky fires with little flame,

• Dirty glass,

• Dirty firebricks,

• Rapid creosote build-up in the chimney,

• Low heat output,

• Short burn times, excessive fuel consumption and

blue/grey smoke from the chimney.

To help avoid large build-ups of tars and creosote within

the stove and the flue system, it is recommended to burn

at high output for at least 0 minutes each day. The use of

Stovax Protector chimney cleaner will also help to reduce

this problem.

10. Fuel Quality (Solid Fuel)

Use only recommended solid fuels, which are approved for

use with closed appliances. Symptoms of poor performance

related to unsuitable fuels include:

• Difficulty getting a fire going and keeping it burning well,

• Smoky fires with little flame,

• Dirty glass,

• Dirty firebricks,

• Short life span for grate, baffles and internal firebricks,

• Permanent staining of glass.

10. Backpuffing

This is caused by a lack of combustion air entering the

firebox causing combustion gases to build up in the firebox

and periodically ignite as small explosions, causing smoke to

puff out of the appliance air inlets and other openings. The

problem will often occur if the air controls are shut soon

after adding new fuel to a very hot fire. To stop backpuffing

occurring open the air controls to increase the combustion

air and increase the burning rate.

10. Flue draught

The chimney has two main functions, which are, to safely

remove the smoke, gases and fumes from the house, and

to provide a sufficient amount of draught (suction) in the

Huntingdon stove to ensure that the fire is kept burning.

Draught is caused by the rising hot air in the chimney when

the Huntingdon stove is lit.

• Dirty glass,

• Rapid creosote build-up in the chimney,

• Low heat output,

• Short burn times, excessive fuel consumption and

blue/grey smoke from the chimney.

To help avoid large build-ups of tars and creosote within

the stove and the flue system, it is recommended to burn

at high output for at least 0 minutes each day. The use of

Stovax Protector chimney cleaner will also help to reduce

this problem (Stovax Part No. 700).

9. Solid fuel: Burn only manufactured briquetted smokeless

fuels, listed as suitable for use with closed heating stoves.

do not burn bituminous coal, ‘petro-coke’ or other

petroleum based fuels, as this will invalidate the product

guarantee

.

9. Fuel consumption at nominal heat output.

As tested at nominal heat output to the requirements of EN

10: 001 for intermittent operation.

9. If you require advice on suitable solid fuels contact your

local Approved Coal Merchant. Details can be obtained by

ringing the Solid Fuel Association advice line on Freephone

0800 600 000. Or their web site at www.solidfuel.co.uk

10. BURNING PERFORMANCE

Description

Fuel Consumption

Kg/hour

Wood

Kg/hour

Briquetted

Smokeless fuel

7057

7058

7058BL

7058LG

Huntingdon 5

1.5

0.69

706

7065

7065BL

7065LG

Huntingdon 8

1.90

0.9

705

7055

7055BL

7055LG

Huntingdon 0

1.90

0.9

706

Huntingdon 5

(wood)

.05

n/a

7060

7061

7061BL

7061LG

Huntingdon 5
(multi-fuel)

.05

0.95

7069

Huntingdon 0

(wood)

.66

n/a

707

7075

7075BL

7075LG

Huntingdon 0
(multi-fuel)

.66

1.6

Advertising