A) cl ose door tr a vel limit, Pr ogr amming limits & for ce, 3a 4 – Genie TRILOG 3064H User Manual

Page 6

Advertising
background image

W

ARNING

Mak

e sur

e door

w

ay is in vie

w and clear of obstacles

and people to a

void injur

y or damage to pr

oper

ty

.

DO NO

T oper

at

e this unit fr

om w

all c

onsole bef

or

e

LIMIT

S and FORCE ar

e set

. S

ev

er

e damage to the

opener can

occur

.

Shuttle MUST be engaged to carriage BEFORE setting limits

. S

ee Installa

tion P

oster (if pr

o

vided) or r

ef

er to

pages 11 and 19.

NO

TE:

If shuttle has NO

T been engaged to

the carriage

, do so no

w

.

©2010 The Genie Company

12/2010

6

PR

OG

RA

M

SE

T

+

SET

TING &

TESTING LIMITS AND FOR

CE

The OPEN (UP) and CL

OSE (DOWN)

D

o

or Limit positions

ar

e c

ontr

olled b

y mak

ing

adjustments using the panel locat

ed on the bott

om of the po

w

erhead

. Begin with

St

ep 1 and c

o

ntinue thr

ough St

ep 10.

Doo

r

Fo

rc

e is set during the final Open/Close

cy

cle of these st

eps

. T

he po

w

erhead will aut

omatically set door speed at slo

w if the

distanc

e betw

een limits is less than 6 f

eet.

Onc

e Limits and F

or

ce ar

e set

DO NO

T use

the

or

butt

ons t

o open or close door

.

A) CL

OSE DOOR

TR

A

VEL LIMIT

NO

TE:

Y

ou can star

t and st

op door mo

vement using either

butt

ons until door

is in c

o

rr

ec

t

open

or closed

position.

W

atch door mo

ve

PR

OGR

AMMING LIMITS & FOR

CE

(C

ontinuing from Installation P

oster if pro

vided)

1

OG

RA

M

SE

T

+

5

PR

OG

RA

M

SE

T

+

PRESS and HOLD

SEE BO

TH

Blue LEDs c

ome ON

SEE r

ound

Blue LED come ON

SEE r

ound Blue

LED flashing

RELEASE

1

2

3

NO

TE:

If one or both LEDs c

ome ON

RED

at this time

, Limits pr

ogr

amming menu

was not ent

er

ed pr

operly

. Y

ou must exit

pr

ogr

amming and r

estar

t.

To exit the pr

ogr

amming func

tion wait

30

sec

onds

for the pr

ogr

amming t

o time out.

PRESS and RELEASE

Please not

e that ther

e is a 30 sec

ond timeout

betw

een each

pr

ogr

amming st

ep

.

A pr

ogr

amming timeout during these st

eps has

occur

ed when

two

RED

flashing LEDs

appear

.

In the ev

ent of a timeout please r

estar

t at St

ep 1.

NOTICE

IF

D

O

O

R

B

E

C

O

M

E

S

O

B

S

TR

U

C

TE

D

I

P

U

LL

D

O

W

N

O

N

H

A

N

D

LE

PR

OG

RA

M

SE

T

PRESS and RELEASE

SEE long Blue LED c

ome ON

If

RED

LED c

omes ON - ST

OP and

exit pr

ogr

amming

.

PRESS and HOLD un

til door is FULL

Y CL

OSED then RELEASE

3a

4

FOR A LIMIT

S PROGR

AMMING QUICK REFERENCE C

ARD

VISIT

WWW

.GENIEC

OMP

ANY

.C

OM

Advertising
This manual is related to the following products: