Chapter 8: Power Over Ethernet Overview

214

GE-DS-82 and 82-PoE Ethernet Managed Switch User Manual

http://www.poweroverethernet.com/articles.php?article_id=52

Microsemi /PowerDsine

http://www.microsemi.com/PowerDsine/

Linear Tech

http://www.linear.com/

The PoE Provision Process

While adding PoE support to networked devices is relatively painless, it should be
realized that power cannot simply be transferred over existing CAT-5 cables. Without
proper preparation, doing so may result in damage to devices that are not designed
to support provision of power over their network interfaces.
The PSE is the manager of the PoE process. In the beginning, only small voltage level
is induced on the port's output, till a valid PD is detected during the Detection period.
The PSE may choose to perform classification, to estimate the amount of power to be
consumed by this PD. After a time-controlled start-up, the PSE begins supplying the
48 VDC level to the PD, till it is physically or electrically disconnected. Upon
disconnection, voltage and power shut down.
Since the PSE is responsible for the PoE process timing, it is the one generating the
probing signals prior to operating the PD and monitoring the various scenarios that
may occur during operation.
All probing is done using voltage induction and current measurement in return.

Stages of powering up a PoE link

Stage

Action

Volts specified

per 802.3af

Volts managed

by chipset

Detection

Measure whether powered device has the
correct signature resistance of 15–33 kΩ

2.7-10.0

1.8–10.0

Classification

Measure which power level class the
resistor indicates

14.5-20.5

12.5–25.0

Startup

Where the powered device will startup

>42

>38

Normal operation Supply power to device

36-57

25.0–60.0