H2854 1 H.P. Variable Speed Plunge Router

-9-

The Model H2854 is supplied with a dust collec-
tion attachment. Routing produces large amounts
of wood dust that can be both damaging to your
lungs as well as messy around your worksite. We
recommend connecting a vacuum system to the
dust collection attachment to keep wood dust to a
minimum. Use a tapered hose end to ensure a
tight connection to the dust collection attachment.
To mount the dust collection attachment to the
router base:

1.

The dust collection attachment has a long
lip on one side and two small lips on the
other side. Line up the lips with the slots in
the router base and snap into place as
shown in

Figure 6

.

2.

Using two Phillips

®

head screws, secure the

dust collection assembly to the base of the
router.

The Model H2854 is supplied with both standard
and metric depth stops. To attach the depth stop:

1.

Loosen the lock knob located on the front of
the router base and slide the desired stop
into the diamond-shaped slot on the upper
base as shown in

Figure 7

.

2.

Tighten the lock knob until the stop is held
securely in place. Be sure not to overtighten
the knob. Depth adjustment will be dis-
cussed later in the manual.

Dust Collection

Figure 6.

Installing dust port.

Depth Stop

Figure 7.

Installing depth stop.