SYSTEM CAPACITY INPUTS

40

GNPR40L certified capacity at salt setting

48

GNPR48L certified capacity at salt setting

NOTE: The 3.0 lbs salt setting (GNPR40L) and the
3.6 lbs salt setting (GNPR48L) are certified using
the 5 bump injector. The 7.5 lbs (GNPR40L), 15 lbs
(GNPR40L), 9 lbs (GNPR48L) and 18 lbs (GNPR48L)
are certified using the 4 bump injector.

13

Installation Instructions

SALT PER REGEN AND CAPACITY

(CONT.)

NOTE: Both SALT PER REGEN and CAPACITY inputs
must be based on the SYSTEM CAPACITY INPUTS
CHART
.

How to determine correct salt dosage and
capacity:

The correct salt dosage and capacity are determined
based on the family size and water hardness. Use the
following procedure and example:

• Daily Water Usage = number of persons in

household x 80 gallons

For a family of 3
Daily Water Usage = 3 x 80 = 240 gallons/day

• Water Hardness – have the water tested or call

your local water company. For this example, 20
grains is assumed.

• Calculate total grains used per day =

gallons/day x hardness = grains/day

240 gallons/day x 20 grains = 4,800 grains/day

• Water softener should be set to regenerate every

5 days.

Req Capacity = 5 days x 4,800 grains/day = 24,000

• Use SYSTEM CAPACITY INPUT table to select

capacity and determine lbs of salt per regeneration.

For GNPR40 use setting at 24,000 grains.

• Program the control:

Capacity: 24,000 grains

Lbs of Salt: 7.0

If water supply has a high level of sediment or iron,
set system to regenerate every 3 days:

• Use the UP

or DOWN

button to select SALT

PER REGEN.

• Press the SET button.

• Use the UP

, DOWN

and LEFT

buttons to

select SALT PER REGEN amount.

• Press the SET button to accept.

• Use the UP

or DOWN

button to select

CAPACITY.

• Press the SET button.

• Use the UP

, DOWN

and LEFT

buttons to

select correct capacity.

• Press the SET button to accept.

Example

of Lbs of Salt

req. per regen

CAPACITY (x 1,000)

GNPR40L

GNPR48L

3.0

14.1

40

N/A

3.6

15.5

15.2

48

4.0

16.5

15.5

5.0

19.0

18.0

6.0

22.0

21.0

7.0

24.0

23.5

7.5

24.4

40

24.3

8.0

25.6

25.0

9.0

27.9

26.1

48

10.0

30.0

30.0

11.0

31.9

31.5

12.0

33.6

33.0

13.0

35.1

34.0

14.0

36.4

35.2

15.0

37.1

40

36.0

16.0

N/A

37.0

17.0

N/A

38.0

18.0

N/A

39.8

19.0

N/A

41.0

20.0

N/A

41.5

21.0

N/A

42.0

22.0

N/A

43.0

23.0

N/A

44.0

24.0

N/A

45.2

25.0

N/A

45.9

26.0

N/A

46.5

27.0

N/A

47.2

28.0

N/A

48.9

48