Problem

Possible Causes

What To Do

Salty tasting or

Unit not sanitized

Complete the Sanitizing Procedures on page 15.

brown/yellow colored

At completion of regeneration cycle (approx. 2 hrs), run water

water after installation

from faucets to purge the salty water.

Low water pressure

Check pressure.
Drain height 8

′ or less, pressure should be minimum of 20 psi.

Drain height above 8

′, pressure should be minimum of 50 psi.

Restricted drain hose

Clean and reconnect drain line.

Check for kinks in drain line.

Brown/yellow

Unit was idle for a period of time

Complete the Sanitizing Procedures on page 15.

colored water

Sounds you might hear

Running water from the unit

This is normal. High water flows in backwash cycle, flushes

during regeneration

into a drain during regeneration

minerals and sediments from resin tank.

cycle

Harmonic noises during regeneration

This is normal.

Clicking

This is normal. This is the sound of various valves opening and

closing as valves cycle through regeneration cycle.

Water has air bubbles

Air in system after installation

Will go away after it runs for a while.

and is cloudy