Troubleshooting tips, Before you call for service, No soft water – most common problems – GE GNPR40L User Manual

Page 19

Advertising
background image

19

Troubleshooting Tips
Save time and money! Review the chart on these pages
first and you may not need to call for service.

Problem

Possible Causes

What To Do

No soft water

Faucet or fixture where sample was

• To conserve salt, the installer may have isolated some fixtures

taken not plumbed to soft water.

(outside faucets, toilets, etc.) from soft water. From the outlet

NOTE: Be sure sample is from a faucet

of the water softening system, trace the water flow path,

that does not mix soft and hard water.

in house plumbing. If soft water is not directed to a faucet

For example, a single lever kitchen faucet,

or fixture where wanted, consult a plumber.

if the cold side is plumbed to hard water.

No salt in the brine tank or

• Check for a salt bridge or, if the tank is empty, refill with

salt bridged

recommended salt. Press (for 3 seconds) the REGEN
button to start an immediate regeneration and restore
soft water supply. See page 17, Breaking a Salt Bridge.

Transformer unplugged at wall outlet or • Check for a loss of electrical power to the water softening
power cable to softener not connected.

system, due to any of these conditions and correct as needed.

Fuse blown or circuit breaker popped

With the power supply restored, observe the faceplate time

on circuit to electrical outlet.

display and read Programming the Control section.

Electrical outlet on a circuit that can

NOTE: The electrical outlet for the softener should be

continuously be switched off

live so it cannot be accidentally switched off.

Manual bypass valve in bypass position • Be sure the flange on the bypass valve knobs are in line with

the pipes.

Valve drain hose pinched, plugged,

• Any restriction in this drain hose may prevent proper

elevated too high or otherwise

operation of the nozzle and venturi and reduce or prevent

restricted

brine draw during regeneration.

Injector and injector screen dirty,

• This will be evident by a high level of water in the brine tank.

incorrectly assembled or damaged

Water level will be greater than 4

″ when the system is in the

service position.

• Refer to Cleaning the Injector and Screen instructions.

With water pressure to the water softening system off, remove
the injector and injector screen. Thoroughly clean and flush.
Check for any damage. Reassemble to valve assembly.

If resin bed is fully exhausted, for

• Complete “back to back” regenerations. Initiate Regeneration

example, after a malfunction, one

cycle, wait 1 minute, then press REGEN again.

regeneration cycle may not fully

See page 14.

restore capacity

NO SOFT WATER – Most Common Problems:

Check the following before calling for service:

• Not enough salt—brine tank should be at least 1/3 full.

• Bypass valve in “Bypass” position—flange on knobs should be in line with pipes

(see page 6).

• Hardness setting too low. Check hardness setting and adjust. Verify hardness of supply

water—from local water company, water test or call the GE Answer Center.

• Salt Bridge—salt solidifies above water level so that brine water is not in contact with

salt. See the Breaking a Salt Bridge section.

Before you call for service…

ge.com

Advertising
This manual is related to the following products: