Flow diagrams, Flow diagrams –29 – GE GNPR40L User Manual

Page 28

Advertising
background image

28

Flow diagrams.

1 Service Position

Inlet

Outlet

Drain

Treated Water

Untreated Water

Valve
No.

Description

Position

1

Brine

Closed

2

Upper Drain

Closed

3

Inlet

Open

4

Bypass

Closed

5

Outlet

Open

6

Lower Drain

Closed

7

Center Dist.

Closed

2 Refill Position

Inlet

Outlet

Drain

Treated Water

Untreated Water

Valve
No.

Description

Position

1

Brine

Open

2

Upper Drain

Closed

3

Inlet

Open

4

Bypass

Closed

5

Outlet

Open

6

Lower Drain

Closed

7

Center Dist.

Closed

3 Brine Draw Position

Inlet

Outlet

Drain

Treated Water

Untreated Water

Valve
No.

Description

Position

1

Brine

Open

2

Upper Drain

Closed

3

Inlet

Closed

4

Bypass

Open

5

Outlet

Closed

6

Lower Drain

Closed

7

Center Dist.

Open

4 Slow Rinse Position

Inlet

Outlet

Drain

Treated Water

Untreated Water

Valve
No.

Description

Position

1

Brine

Open

2

Upper Drain

Closed

3

Inlet

Closed

4

Bypass

Open

5

Outlet

Closed

6

Lower Drain

Closed

7

Center Dist.

Open

Advertising
This manual is related to the following products: