-24-

Model g0724 (Mfg. since 09/11)

When adjusted to 90˚, the miter gauge should be
perpendicular to the face. if it is not, follow this
procedure.

to calibrate the miter gauge:

1. disConnECt MaChinE FroM poWEr!

2. using a try square or machinist’s square, set

one edge against the face of the miter gauge
and the other against the face of the disc, as
shown in

figure 26.

Miter Gauge

Calibration

3. loosen the lock knob on the miter gauge,

adjust the face of the miter gauge so it is
flush with the edge of the square, and then
tighten the gauge lock knob and verify the
setting.

4. using a phillips head screwdriver, loosen the

degree scale pointer, position the pointer to
90˚, and retighten the screw.

5. recheck the miter scale accuracy with the

square, and repeat the adjustment process if
necessary.

figure 26. squaring miter gauge to disc.

When the table tilt is set to 0˚, it should be posi-
tioned perpendicular to the sanding disc face. if it
is not, follow this procedure.

to calibrate the table tilt:

1. disConnECt MaChinE FroM poWEr!

2. using a try square or machinist’s square, set

one edge on the table surface and the other
against the face of the disc, as shown in

figure 27.

table tilt Calibration

Note: This adjustment can be done with the
sandpaper installed, although it is more pre-
cise if the sandpaper is not installed.

3. loosen the lock levers and adjust the table

angle until it is perpendicular to the disc, then
tighten the lock levers while holding the table
in place.

4. using a phillips head screwdriver, loosen the

degree scale pointer, index the pointer on 0˚,
and retighten the screw.

5. recheck the scale accuracy with the square,

and repeat the adjustment process if neces-
sary.

figure 27. squaring the table.