Rear Access Re-lamping and Fixed Aiming—

The

Ultra

Sport floodlight’s rear reflector cover serves as an access

door to the optical for re-lamping and maintenance without any
adjustment to the aiming of the floodlight. The cover hinges
open 90 degrees for easy access.

5

Ultra

Sport

TM

Floodlight

Broken Glass Shutdown Circuit—

Metal halide light sources

produce ultraviolet (UV) radiation. If a person is directly exposed,
this radiation can cause discomfort and sometimes permanent eye
damage. Normally UV radiation is absorbed in a lamp’s outer bulb
or jacket.

Unjacketed lamps rely on a luminaire’s optical lens to absorb

UV. If the lens of a fixture that uses an unjacketed lamp is broken,
the escaping ultraviolet radiation can create a potential health risk
to players and spectators.

Because of this risk, Ultra

Sport floodlight is the first sports

lighting fixture to feature a Broken Glass Shutdown Circuit .

The system continuously senses the integrity of the front door

glass. In the unlikely event that the lens is broken, the system
automatically shuts off power to the lamp. A Broken Glass
Shutdown Circuit is a standard feature on all Ultra

Sport

luminaires.

Instant Hot Restart—

Ultra

Sport floodlights can be

ordered with a new optional instant hot restart feature. After a
momentary power interruption or line voltage dip which
causes the lamp to extinguish, the hot restart pulse will restart
the lamp within two seconds of power reapplication.