3.5 Having run the gas supply to the stove, PURGE THE SUPPLY

PIPE, this is essential to expel any debris that may block the

gas controls. Connect the gas supply to the 8mm

compression elbow at the right-hand rear corner of the

stove. There is a cutout in the right-hand rear leg to enable a

direct straight connection to be made to the rear of the

stove. See diagram 2. A gas soundness check must be

completed up to the gas inlet connection.

3.6 Open the second carton and carefully remove the steel

casing components. Remove the protective plastic coating

from the two side assemblies. Attach the four lugs to the

front side of each panel and lower them onto the engine

assembly until the tabs locate as shown. Check that the feet

are touching the hearth. See Diagram 3.

3.7 Secure the upper front panel using the 4 nuts and bolts

provided. See diagram 4.

3.8 Locate the lower panels onto the lugs as shown. See diagram

5.

3.9 Place the steel top onto the casing so that the 2 lugs on the

undeside locate the top centrally within the casing. Place the

cast iron grill into the recess in the centre of the top panel

and locate the blanking plate into the grill (if required). See

Diagram 6.

3.10 Check the pull of the flue system by applying a lighted

smoke pellet to the flue system opening. If there is a definite

flow into the chimney, proceed with the installation. If not,

warm the chimney for a few minutes.
IF THERE IS STILL NO DEFINITE FLOW, THE

FLUE MAY REQUIRE ATTENTION - SEEK EXPERT

ADVICE

3.11 The flue system may now be connected to the stove. Ensure

that all joints are sealed with a suitable fire resistant sealant.

It is also recommended that a physical retention method be

used at the flue spigot joint, self-tapping screws being

favoured.

3.12 Connect a suitable pressure gauge to the test point

located on the inlet fitting, and turn the gas supply on. Light

the appliance to maximum and check that the supply

pressure is as stated on the databadge. Turn the gas off and

replace the test point screw. Turn the gas on and check the

test point for gas soundness.