For increased energy efficiency, some
water heaters have been supplied with
two 24” sections of pipe insulation.

Please install the insulation, according to
the illustrations above, that best meets
your requirements.

DO

DO

check inlet gas pressure to ensure

that it is within the range specified on the
rating plate.

DO

provide adequate air for combustion

and ventilation as discussed in the Use and
Care Manual and the National Fuel Gas Code.

DO

maintain proper clearances to

combustibles as specified on the rating
plate.

DO

allow enough time for joint cement

vapors to dissipate BEFORE applying power
to the water heater.

DO

ensure that the venting system

complies with the guidelines found in the Use
and Care Manual and National Fuel Gas
Code.

DO

contact a qualified service technician

if the pilot or main burner will not stay lit. The
burner chamber is designed to be sealed
utilizing a gasket and tamper resistant
screws.

DON’T

DON’T

block or restrict Combustion Air

Inlet Openings or the Flammable Vapor
Sensor located around the lower portion of
the water heater jacket.

DON’T

block or restrict the Blower

Assembly Dilution Air holes.

DON’T

remove the Burner Access Door

unless absolutely necessary. This should
only be done by a qualified service technician.
A new burner access door gasket must be
installed on any burner access door that has
been removed.

DON’T

install this water heater where

standing water may occur. The base of the
water heater is meant to be mounted on a
dry surface.

DON’T

operate the water heater if the

sight glass or burner access door grommet
is damaged or broken.

R

E

L

I

E

F

V

A

L

V

E

CO

LD

HO

T

Typical vertical piping arrangement

R

E

L

I

E

F

V

A

L

V

E

CO

LD

HO

T

Typical horizontal piping arrangement

During Installation of this water heater...........

Heat Trap

Hot and Cold Pipe Insulation Installation

Burner Access
Door Grommet

Sight Glass

For increased energy efficiency, some
water heaters have been supplied with
factory installed 3/4” NPT heat traps in
the hot outlet line and cold water inlet
line.

These heat traps may require a minimum
of one (1) 90

°

3/4” NPT elbow and may

require an additional 90° 3/4” NPT elbow
or a 3/4” coupling depending on your
installation needs. See Illustration of
nipples and heat traps on page 31.

NOTICE: If pipe insulation
is used, ensure that the
thickness does not
exceed ½”. Insulation
thicker than ½” can
interfere with the Blower
Assembly Dilution Air
Holes.

19

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

T

roubleshooting Tips

Customer Service

Blower Assembly Dilution Air Holes

Location of Dilution Air Holes