Pump Power Head Replacement

311283D

13

2.

Tighten power head bolts (7). Torque bolts to 400 +
10 in-lb (45 + 1 N•m).

3.

Attach hoses (100, 101) to head (75). Torque to 450
+ 10 in-lb (50.84 N•m).

4.

To purge air from hydraulic lines, increase pressure
enough to start hydraulic motor stroking and allow
fluid to circulate for 15 seconds.Turn pressure
down. Turn prime valve horizontal (closed).