Operation, General repair information, Pressure relief procedure – Graco Inc. 253471 User Manual

Page 5: Grounding

Advertising
background image

Operation

311283D

5

Operation

Pressure Relief Procedure

1

Set pump valve OFF. Turn engine OFF.

2

Turn pressure to lowest setting. Trigger gun into pail to
relieve pressure.

3

Open prime valve (vertical).

If you suspect that the spray tip or hose is completely

clogged, or that pressure has not been fully relieved after

following the steps above, VERY SLOWLY, loosen tip

guard retaining nut or hose end coupling to relieve pres-

sure gradually, then loosen completely. Then clean tip

and hose.

General Repair Information

Install belt guard before operation of sprayer and
replace if damaged. Belt guard reduces risk of
pinching and loss of fingers.

To reduce risk of serious injury,:

Keep all screws, nuts, washers, etc. removed during
repair procedures. These parts usually are not pro-
vided with replacement kits.

Test repairs after problems are corrected.

If sprayer does not operate properly, review repair
procedure to verify you did it correctly. See Trouble-
shooting
, page 7.

Do not touch moving parts with fingers or tools while
testing repair.

Grounding

Ground sprayer with grounding clamp to earth ground
for safe sprayer operation.

System pressure must be manually relieved to prevent
it from starting or spraying accidentally. Fluid under
high pressure can be injected into the skin and cause
serious injury. To reduce risk of injury from injection,
follow this procedure whenever you are instructed to
relieve pressure, stop spraying, service equipment or
install or clean spray tip. Read warnings, page 4.

TIA

Hydraulic system and engine may become very
hot during operation and could burn skin if
touched. Flammable materials spilled on hot, bare
motor could cause fire or explosion. Have belt
guard in place during operation to reduce risk of
pinching or loss of fingers.

Advertising