Installation preparation, Warning – GE Monogram ZDP364LD User Manual

Page 10

Advertising
background image

Installation Preparation

4-WIRE POWER CORD INSTALLATION

NOTE: A 4-wire cord is connected to the range
at the factory. Use the following steps to change
an existing installation from a 3-wire cord back
to a 4-wire cord.

WARNING

The neutral wire of the supply circuit must
be connected to the neutral terminal located
in the lower center of the terminal block.
The power leads must be connected
to the lower left and the lower right
terminals of the terminal block. The 4th
grounding lead must be connected to
the frame of the range with the ground
plate and the ground screw.

•Remove the 3 lower terminal screws from

the terminal block. Remove the ground screw
and ground plate and retain them.

Remove the ground strap. DO NOT DISCARD

THE GROUND STRAP OR ANY SCREWS.

•Insert the one ground screw into the power cord

ground wire terminal ring, through the ground
plate and into the frame of the range.

•Insert the 3 terminal screws (removed earlier)

through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position
of the terminal block. Tighten screws securely
into the terminal block.

Before

After

Terminal
Block

Terminal
Block

Neutral
Terminal

Neutral Terminal

Ground Strap

Ground Plate
(grounding to
range)

Ground
Screw

Ground Strap

or

3-WIRE POWER CORD INSTALLATION

NOTE: A 4-wire cord is connected to the range
at the factory. Use the following steps to change
the range to a 3-wire cord.

WARNING

The neutral or ground wire of the power cord
must be connected to the neutral terminal located
in the center of the terminal block. The power leads
must be connected to the lower left and the lower
right terminals of the terminal block.

•Remove the ground strap (located at the right

side of the terminal block) and connect between
the center lower portion of the terminal block
to the frame of the range.

•Remove the 3 lower terminal screws from

the terminal block. Insert the 3 terminal screws
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position
of the terminal block. Tighten screws securely
into the terminal block.

DO NOT remove the ground strap connection.

Ground
Strap

Terminal Block
(appearance
may vary)

Neutral
Terminal

Power Cord

Ground
Plate

10