CHANGE GRIDDLE ORIFICE

(if present)

Locate the 3/4" long griddle orifice.
Select for your gas type. LP

.047, NAT

.076

A. Lift off the

griddle flue
cover. Remove
the 2 inside
clamping
screws.

B. Lift out the

cast-iron
grease trough.
Slide the
griddle toward
the rear and
out of the
hold-down
tabs along the
bottom.

C. Carefully lift and hold

the griddle while pulling
additional length of the
capillary from the entry
hole. Stand the griddle on
end in the grease sump.

D. Remove the 2 hold-down

screws at the rear of the
burner.
Pull the burner straight
back toward the rear and
out of the gas inlet.

E. Use a 1/2” deepwell

socket to remove and
replace the orifice.

Reverse these steps to reassemble the griddle.
Push excess capillary back into the entry hole.
Place the unused orifice in the holder for possible
future use.

5

23

Installation Instructions for Gas Conversion

ADJUST BURNER FLAMES

Normally, burners do not need further adjustment.
Make adjustments only when necessary.

A. Turn on the gas. Plug in electrical cord.
B. Turn all burners on highest setting and check

the flames. They should be blue in color. When
using LP gas, the flames may have some yellow
tipping at the ends of the flame. Foreign particles
in the gas line may cause an orange flame at first,
but this will soon disappear.

C. Turn the burner knob to “LO” while observing the

flame.

Adjust the setting of the upper row of flames using
the valve bypass screw as follows:
Adjustments must be made with two other burners
in operation on a medium setting. This prevents
the upper row of flames from being set too low,
resulting in the flame being extinguished when
other burners are turned on.
D. To adjust the flame, remove the knobs. Insert a small

flat-blade screwdriver into the hole in the center
of the valve stem to engage screw.

• If the flames are too small or flutter,

turn the screw counterclockwise.

• If the flames are too large, turn the screw

clockwise.

E. Make the adjustment by slowly turning the screw

until flame appearance is correct.

6

Once the conversion is complete and checked, fill out the conversion label and affix the label near the rating label. For ranges,
place the label beneath the control panel. For rangetops, place the label on the bottom of the unit.

Capillary

Front of Range

B

C

D

E

Back of Range

Griddle Flue Cover

Clamping Screws

Leveling Screws

A

NOTE: Remove

the 2 screws

positioned on

the inside only.

Do not remove

the outermost

screws—they

are for leveling.

Advertising