Grizzly 2HP Magnetic G8291 User Manual

Instructions, Color key

Advertising
background image

BLACK
GREEN
RED

COLOR KEY

Bk

Gn

Rd

YELLOW

3

L2

5

L3

13

NO

2

T1

4

T2

6

T3

14

NO

TEST

TRIP IND.

97 NO

98 NO

95 NC

96 NC

2

T1

4

T2

6

T3

O R

54

NO

NO

53

ON

OFF RESET

2 HP 110V Motor

110 Volt

Single-Phase

Power Source

M

A

1

L1

TECO

CU-
16

Ground

Contactor TECO

CU-16 (110V Coil)

Thermal Overload

Relay TECO RHN-10K

(22–30A)

IMPORTANT: This magnetic switch toggles a motor ON and OFF, and helps provide thermal overload pro-
tection for the motor if the operating temperature gradually increases due to heavy work loads. The thermal
overload relay inside is not designed to cut power in the event of a sudden motor overload or stall. To help
protect a motor from this type of overload, the power supply circuit must be properly sized for the full-load
current rating of the motor.

OPERATION: When pushed, the green ON button on the outside cover of the magnetic switch allows cur-
rent to flow to the magnetic coil, which pulls the contactor closed. The main current then passes through
the thermal overload relay to the motor. If the motor begins to overheat, the relay breaks the magnetic field,
which opens the contactor and cuts current to the motor. The red OFF button manually breaks the magnetic
field, which opens the contactor and disconnects the current to the motor.

Figure 1. Model G8291 magnetic

switch.

Electrocution or

fire could occur if

this switch is not

installed or adjust-

ed by a qualified

electrician!

MODEL G8291

2 HP 110V MAGNETIC

SWITCH

INSTRUCTIONS

Advertising