RS-232 SERIAL INTERFACE

This feature allows for easy integration into automated systems capable of
transmitting RS-232 commands. Use the settings below to confi gure the RS-232
port of the user’s system.

Transmitting the appropriate numeric ASCII character will simulate key-presses
on the IR remote control.

RS-232 Settings

Bits per second .............................................................................................19200

Data bits ............................................................................................................... 8

Parity ............................................................................................................. None

Stop bits ................................................................................................................1

Flow Control .................................................................................................. None

Binary Table

ASCII

Corresponding

RMT-848IR

Button

Binary

ASCII

Corresponding

RMT-848IR

Button

Binary

1

1

0011 0001

A

A

0110 1001

2

2

0011 0010

B

B

0110 0001

3

3

0011 0011

C

C

0110 0010

4

4

0011 0100

D

D

0110 0011

5

5

0011 0101

E

E

0110 0100

6

6

0011 0110

F

F

0110 0101

7

7

0011 0111

G

G

0110 0110

8

8

0011 1000

H

H

0110 0111

5 4 3 2 1

9 8 7 6

1 2 3 4 5

6 7 8 9

Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface