Installation – Mega Catch Mini User Manual

Page 12

Advertising
background image

� ��

���� ���

���� ��� ������� ��� ��

�� ����� ��� ����� ���

���� �� ��� ������ ������

���� ��������

���� ������

���� ���� ����

������� ������

������� �����

�������� ���� ����

����� ��� ��� ����

���� �������

����� ��� ���� �������� ����
�������� � ������ ���� ���
���������� �� �������������

I

NSIDE

V

ERTICAL

I

NSTALLATIONS

:

Figure 14: Inside Vertical Installation.

1. Choose a stove location that is ideal.

See the section “D

ECIDING

W

HERE

TO

L

OCATE

YOUR

P

ELLET

A

PPLIANCE

.”

2. Place a non-combustible hearth pad

where necessary.

3. Place the unit on the hearth pad (if

installed on a combustible surface)

and space the unit in a manner so

when the pellet vent is installed

vertically, it will be 3” (7.5 cm) away

from a combustible wall.

4. Install the tee with clean out.
5.

I

nstall the pellet vent upward

from there. When you reach the

ceiling, make sure that the vent

goes through the ceiling fire stop.

Maintain a 3” (7.5 cm) distance

to combustibles and keep attic

insulation away from the vent pipe.

Maintain an effective vapor barrier.

6. Finally, extend the pellet vent to go

through the roof flashing.

7. Ensure that the rain cap is

approximately 24” (600 mm) above

the roof.

12

Wall framing

Wall thimble

Termination cap

Vertical section

of vent pipe

Horizontal frame

for thimble

90° elbow

Concrete Wall

Clean out tee

Wall framing

Wall thimble

Termination cap

Vertical section of vent pipe

Horizontal frame for thimble

Clean out tee

90° elbow

Wall strap

Figure 12: Venting horizontally with rise.