6 Technical Specifications

Specifications

Parameter

Value

Comment

Accuracy ±2%

Resolution ±1%

Number of Tank Types

16

Fuel, Fresh Water, Waste Water, Live Well, Oil, etc.

Number of Tanks per Tank Type

16

16 Tanks per Tank Type Numbered 0-15

Maximum Tank Depth

40” (1.02m)

Minimum Depth Reading

2” (5.08cm) Sensor Deadband

Support for Irregularly Shaped
Tanks

Yes

Can be Calibrated for any Shape Tank

Programmable Tank Capacity

Yes

Allows Displays to Calculate Amount Remaining

Maximum Tank Angle

Without focus tube

15°

With focus tube


Certifications

Parameter

Comment

NMEA 2000

Level B+

Maritime Navigation and Radiocommunication Equipment & Systems

Tested to IEC 60945

FCC and CE Mark

Electromagnetic Compatibility


NMEA 2000

®

Parameter Group Numbers (PGNs) - See Appendix A for Details

Description

PGN #

PGN Name

Default Rate

Periodic Data PGNs

127505

Fluid Level

0.4 Times/Second

Response to Requested PGNs

126464

PGN List (Transmit and Receive)

N/A

126996 Product

Information

N/A

126998 Configuration

Information

N/A

Protocol PGNs

059392

ISO Acknowledge

N/A

059904 ISO

Request

N/A

060928 ISO

Address

Claim

N/A

065240 ISO

Address

Command

N/A

126208 NMEA

N/A


Electrical

Parameter

Value

Comment

Operating Voltage

9 to 16 Volts

DC Voltage

Power Consumption

<100mA

Average Current Drain

Load Equivalence Number (LEN)

2

NMEA 2000

®

Spec. (1LEN = 50mA)

Reverse Battery Protection

Yes

Indefinitely

Load Dump Protection

Yes

Energy Rated per SAE J1113