Mechanical

Parameter

Value

Comment

Size

3.9”” x 1.2” x 1.0”

(99mm x 30.5mm x

25.4mm)

Interface Component

2.7” dia. X 0.9”

(68.6mm dia. x 22.9mm)

Sensor Component

8.5” (215.9mm)

Interconnecting Cable

Weight

12 oz. (340g)

Mounting

SAE J1810 5-hole bolt

pattern

Can mount to 1.25” BSP or 1.5” NPT using
available adapters

Environmental

Parameter

Value

IEC 60945 Classification

Exposed

Degree of Protection

IP67

Operating Temperature

-25°C to 55°C

Storage Temperature

-40°C to 70°C

Relative Humidity

93%RH @40° per IEC60945-8.2

Vibration

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s

2

per IEC 60945-8.7

Rain and Spray

12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8

Solar Radiation

Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10

Corrosion (Salt Mist)

4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12

Electromagnetic Emission

Conducted and Radiated Emission per IEC 60945-9

Electromagnetic Immunity

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Safety Precautions

Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12

7 Technical Support

If you require technical support for Maretron products, you can reach us in any of the following
ways:
Telephone:

1-866-550-9100

Fax:

1-602-861-1777

E-mail:

[email protected]

World Wide Web:

http://www.maretron.com

Mail:

Maretron,

LLP

Attn: Technical Support

9014 N. 23

rd

Ave Suite 10

Phoenix, AZ 85021 USA

Advertising