Mdr 24/ 96, Adat optical hookup (dio•8 or opt•8) – Magma MDR 24/96 User Manual

Page 22

Advertising
background image

22

MDR 24/96

MDR

24/

96

Note:

Note:

Note:

Note:

Note: Determining

which unit in

Figures

2 & 3 provides master

clock depends on

your application. For

information on ad-

vanced applications,

see the Technical

Reference manual.

ADAT Optical Hookup (DIO•8 or OPT•8)

Cables & Hardware

(3) DIO

8 or OPT

8 cards for MDR24/96

(3) DIO

8 or OPT

8 cards for D8B

(1) Clock I/O card for D8B
(6) ADAT Optical cables
(1) 75

Ω BNC word clock cable

Hookup

1. Connect three ADAT Optical cables from the MDR24/96 Optical Outputs to

the Optical Inputs on the corresponding D8B I/O cards.

2. Connect three ADAT Optical cables from the MDR24/96 Optical Inputs to

the Optical Outputs on the corresponding D8B I/O cards.

3. When ADAT Optical is used, the D8B must have a Clock I/O card

installed. To make the D8B the clock master, connect its Word Clock Out
to the MDR24/96 Word Clock In. To make the MDR24/96 the clock
master, connect its Word Clock Out to the D8B Word Clock In.

MDR24/96 Settings

1. If you have DIO•8 cards installed, set the Tape Input and Tape Output

format for each card to ADAT. OPT•8 cards need no configuration.

2. If the MDR24/96 is the clock master, set the Sample Clock to Internal; If

the MDR24/96 is a clock slave, set the Sample Clock to Word Clock and
depress the 75

Ω termination button on the Sync card.

3. Set the Sample Rate to 44.1 kHz or 48 kHz according to your preference.

Console Settings

1. If you have DIO

8 cards installed, set the Tape Input and Tape Output

format for each card to ADAT. OPT

8 cards need no configuration.

2. If the D8B is the clock master, set the Sample Clock to either 44.1 k

Internal

or 48 k Internal; if it is a clock slave, then set the Sample Clock

to either 44.1 kHz or 48 kHz. Set the Sample Rate to match the Sample
Rate

selected on the MDR24/96.

Advertising