Slave master (adat a) slave (dat) slave (adat b) – M-AUDIO PROFIRE 2626 User Manual

Page 35

Advertising
background image

User Guide

34

ProFire 2626

Scenario 2: ProFire 2626 Slaved to an Optical Input

If you prefer to use another device as clock master, you will need to configure that device to act as master and select
that device’s input on ProFire 2626 as the sync source This locks (or “slaves”) ProFire 2626 (and any other devices
connected to ProFire 2626) to that master device

In Figure 2 below, a digital multi-track recorder with an ADAT optical output is configured as clock master ProFire 2626
and other devices (a DAT machine and another multi-track recorder, in this case) receive and lock to the clock of the
“master” ADAT device

12V DC

MIDI

S/PDIF

Word Clock

In A

Out A

7

5

3

8

7

6

5

4

3

2

1

In B

Out B

Optical

Line Outputs

3.5A

+

Mic/Line Inputs

1

8

6

4

2

MIDI

S/PDIF

Word Clock

In A

In B

Out A

Out B

S/PDIF

(RCA)

Slave

Master (ADAT A)

Slave (DAT)

Slave (ADAT B)