Master Lock F-64TPG User Manual

Page 19

Advertising
background image

19

ACTIVATE FAULT FIND - Activates a multiple diagnostic test report. For installer's use

only. If accidentally enabled, press RESET to exit. Note: This selection only appears

with a Master I-FOB inserted in the Touchpad.


RESET SYSTEM TBL - System troubles display and sound at the Touchpad. Correct-

ing the trouble will clear most indications, however the following error codes will require
manual reset: E13; E19; E20 and E22. (See SYSTEM TROUBLE ERROR CODES for
a description of error codes). Note: This selection only appears with a Master I-FOB

inserted in the Touchpad.


ACTIVATE DIALER TEST – Allows a central station communication test to be initiated,

transmitting a Test Timer signal. For installer's use only. If accidentally enabled,
press RESET to exit. Note: This selection only appears with a Master I-FOB inserted

in the Touchpad.


ENTER LOG MENU – The Log Menu provides a list of logged events. DISPLAY

ALARM LOG displays the most recent alarm events. DISPLAY TOTAL LOG dis-
plays the most recent events of all types. DISPLAY FIRE LOG displays the most re-
cent fire events. DISPLAY OP/CL LOG displays the most recent openings and clos-
ings and DISPLAY SYSTEM LOG displays the most recent system events. Note:
This selection only appears with a Master I-FOB inserted in the Touchpad.


ACTIVATE PROGRAM - Activates the User Program Mode. See page 21 for more infor-

mation. Note: This feature is disabled while armed. Note: This selection only ap-
pears with a Master I-FOB inserted in the Touchpad.

T O U C H P AD M E N U M O D E

ACTIVATE
FAULT FIND

Y/N

RESET
SYSTEM TBL

Y/N

ACTIVATE
DIALER TEST

Y/N

ENTER LOG
MENU Y/N

ACTIVATE
PROGRAM Y/N