Keyboard/TrackPoint-Related
Symptoms

Symptom/Error

FRU/Action in Sequence

Keyboard (one or more
keys) doesn’t work.

v Go to “FRU tests” on page 98.
v Reseat keyboard cable.
v Keyboard
v System board

TrackPoint does not
work.

v Go to “FRU tests” on page 98.
v Reseat keyboard cable.
v Keyboard
v System board

Indicator-Related Symptoms

Symptom/Error

FRU/Action in Sequence

Indicator incorrectly
remains off or on, but
system runs correctly.

v Reseat LED board (12.1″); Reseat

Inveter/LED board (13.0

″/13.3″)

v LED board (12.1″); Inveter/LED

board (13.0

″/13.3″)

v System board

Power-Related Symptoms

Symptom/Error

FRU/Action in Sequence

Power shuts down during
operation.

v Go to “Power systems checkout” on

page 36.

v AC Adapter
v Battery assembly
v Keyboard
v System board

The system doesn’t
power on.

v Go to “Power systems checkout” on

page 36.

v AC Adapter
v Battery assembly
v Keyboard
v System board

The system doesn’t
power off.

v Go to “Power systems checkout” on

page 36.

v Hold and press the power switch

for more than 4 seconds.

v Keyboard
v System board