Error Code

Message

FRU/Action in Sequence

071

CMOS Battery
Bad

v Backup battery (RTC

battery)

v Enter BIOS Utility and

execute

″Load Setup

Default Settings

″; then

reboot the system.

v System board

072

CMOS Checksum
Error

v Enter BIOS Utility and

execute

″Load Setup

Default Settings

″; then

reboot the system.

v Backup battery (RTC

battery)

v System board

110

Incorrect
Password
Specified, System
Halted.

v Set SW1 Pin 4 (Check

Password) to

″0″.

v Enter BIOS Utility and clear

password.

v Set SW1 Pin 4 (Check

Password) to

″1″.

252

VPD Checksum
Error

v Run ThinkPad Hardware

Maintenance Diskette.

v Input correct data.

Beep Symptoms

Symptom/Error

FRU/Action in Sequence

Five short beeps and
then system shut down
without any message on
screen

v Battery power critical low (Connect

the AC adapter or install a fully
charged battery.)

v Battery assembly.

One long beep and one
short beep (In-proper
speed DIMM module
(66MHz) be inserted.)

v DIMM
v System board