Middleby Marshall PS624E User Manual

Page 18

Advertising
background image

14

SECTION 2
INSTALLATION

III. ELECTRICAL CONNECTION INFORMATION

FOR PS624-SERIES OVENS.

WARNING

Authorized supplier personnel normally ac-
complish the connections for the ventilation
system, electric and gas supplies, as ar-
ranged by the customer. Following these
connections, the factory-authorized installer
can perform the initial startup of the oven.

Check the oven data plate (Figure 2-10) before making any
electric supply connections. Electric supply connections
must agree with data on the oven data plate.

NOTE: The electric supply installation must satisfy the
requirements of the appropriate statutory authority, such
as the National Electrical Code (NEC), ANSI/NFPA70,
(U.S.A.); the Canadian Electrical Code, CSA C22.2; the
Australian Code AG601; or other applicable regulations.

A fused disconnect switch or a main circuit breaker
(customer furnished) MUST be installed in the electric
supply line for each oven; it is recommended that this
switch/ circuit breaker have lockout/tagout capability. The
electric supply connection must meet all national and local
electrical code requirements. Copper is the recommended
material for the electrical supply conductors.

IV. ELECTRIC SUPPLY

Electrical connection is made through a cord and plug.
A cord, plug and strain relief is supplied for Domestic
oven models, only. International ovens must supply,
See Electrical Specifications chart on page 2.

The supply conductors must be of the size and
material (copper) recommended to provide the cur-
rent required; (refer to the data plate for the ampere
specifications). The power cord plug must not be
altered in any manner. Do not remove the grounding
prong from the electrical plug supplied, as this can
cause an unsafe operating condition.

Figure 2-10. Typical Electric Oven Data Plate

International CE Plate

Domestic Plate

Figure 2-11. Junction Connection Box

ELECTRICAL

INLET

Advertising