1. front panel controls – Miller Electric Big Blue 401DXQ User Manual

Page 26

Advertising
background image

OM-173 413 Page 22

SECTION 5 – OPERATING THE WELDING GENERATOR

5-1.

Front Panel Controls

Ref. ST-188 449

.

This unit has a max OCV control circuit
that resets the Amperage/Voltage Con-
trol to maximum when the arc breaks.
When an arc is struck, weld output con-
trol returns to the front panel or remote
control setting. The Amperage/Voltage
Control adjusts amperage only when
welding and does not adjust open-circuit
voltage.

1

Ampere Range Switch

Y

Do not switch under load.

2

Amperage/Voltage Control

Control adjusts amperage within range se-
lected by Ampere Range switch.

Weld output would be 140 A DC with controls
set as shown (50% of 90 to 190 A).

3

DC Voltmeter (Optional)

4

DC Ammeter (Optional)

5

Remote A/V Switch And Receptacle
(See Section 5-3)

6

Magnetic Shutdown Switch (Optional)

Use switch during start-up to bypass option-
al engine shutdown system. System stops
engine if oil pressure is too low or oil temper-
ature is too high.
7

Engine Control Switch

To Start: turn switch to Start while pressing
Shutdown switch. Release switches when
engine starts.

.

If the engine does not start, let engine
come to a complete stop before attempt-
ing restart.

In Run position, engine runs at weld/power
speed. In Run/Idle position (optional), engine

runs at idle speed at no load and weld speed
with load applied.

To Stop: turn switch to Off position.

8

Battery Charging Warning Light

Light goes on when battery is not charging.

9

Oil Pressure Warning Light

Light goes on if oil pressure is too low. Light
also goes on if oil temperature is too high (if
unit has automatic shutdown option).

Y

Stop engine and fix trouble if either
light goes on.

10 Engine Hour Meter

11 Oil Temperature Gauge/Switch

(Optional)

12 Oil Pressure Gauge/Switch (Optional)

1

2

11

12

5

3

4

6

7

10

8

9