OM-173 413 Page 24

SECTION 6 – OPERATING AUXILIARY EQUIPMENT

6-1.

120 Volt And 240 Volt Duplex Receptacles

Ref. ST-188 449

Y

If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.

.

If a circuit breaker continues to open,
contact Factory Authorized Service
Agent.

.

Auxiliary power is not affected by weld
output.

1

240 V 15 A AC Receptacle RC1

2

120 V 15 A AC Receptacle RC2

Receptacles supply 60 Hz single-phase
power at weld/power speed.

3

Circuit Breakers CB1 And CB2

CB1 protects RC1 and CB2 protects RC2
from overload. If CB1 or CB2 opens, the re-

ceptacle does not work. 120 volts may still
be present at RC2.

Maximum output from each duplex recep-
tacle is 1.8 kVA/kW, and 3 kVA/kW from all
receptacles.

EXAMPLE: If 10 A is drawn from RC1, only
5 A is available at RC2:

(240 V x 10 A) + (120 V x 5 A) = 3.0 kVA/kW

1

2

3

6-2.

Optional Auxiliary Power Receptacles

Ref. ST-188 449 / Ref. ST-169 671-A

Y

If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.

.

If circuit breaker continues to open,
contact Factory Authorized Service
Agent.

.

Auxiliary power is not affected by weld
output.

GFCI Receptacle Option

1

120 V 15 A AC GFCI Receptacle
GFCI1

Auxiliary power output and circuit breaker

protection is the same as standard recep-
tacles (see Section 6-1).

If a ground fault is detected, GFCI Reset
button pops out and receptacle does not
work. Check for faulty tools plugged in re-
ceptacle. Press button to reset.

.

At least once a month, run engine at
weld/power speed and press test but-
ton to verify GFCI is working properly.

2

240 V 13 A AC British Receptacle
RC1

3

240 V 16 A AC South African Recep-
tacle RC1

4

240 V 10 A AC Australian Receptacle
RC1

5

Circuit Breaker CB1

Receptacle supplies 60 Hz single-phase
power at weld/power speed. Maximum out-
put is 3 kVA/kW.

CB1 protects the receptacle from overload.
If CB1 opens, the receptacle does not work.
120 volts may still be present at the 240 V
receptacle.

Combined output of all receptacles is 3 kVA/
kW.

5

4

3

5

5

2

1