Maintenance

Although this monitor requires little care, you can still maintain its condition and performance
by following these steps:

• Keep the system away from excessive moisture, extreme heat or cold, and magnetic fields.
• Occasionally clean the monitor screen with damp soft cloth.

Should you experience any problem with the system please refer to the troubleshooting guide
prior to returning your system for repair.

Note 1: The user should not attempt to service the unit beyond that described in the operating
instructions. All other servicing should be referred to qualified personnel.

Note 2: Do not expose the unit to water or excessive moisture. This could cause electrical
shorts, fire or other damage.

Troubleshooting

Symptoms

Solutions

Unstable Image

• Low-Voltage – Check Battery
• Check Generator
• If the systems is wireless move vehicle to

another location, as the problem may be
caused by outside interference.

Cloudy Image

• Clean Dirty Camera Lens
• Clean Dirty Monitor Lens
• Adjust Contrast
• Adjust Brightness

Only qualified personnel should remove the cover or service this unit. The warranty will become invalid
if factory security seal is broken.

No Power/Picture

• Check Fuses
• Check if AV Cable is Properly Connected

to Monitor

No Sound

• Check Volume Level and Audio

Connection

Note: The speaker is only operational when
the vehicle is put into reverse and is auto-
matically activated.

No Color

• Check Color Level Settings

Upside Down or Inverted Image

• Check Horizontal and Vertical Settings

Monitor Does Not Display Image When
Vehicle is in Reverse

• Check the Green Reverse Trigger Wire for

Proper 12 Volt Connection.

• Check Video Inputs to Ensure they are

Properly Connected