Setup, Network clock sync, Using the control panel – Momentum Sales & Marketing MO8ME User Manual

Page 13

Advertising
background image

13

Momentum mo8me Manual

Connection and Setup

Chapter 2

Setup

Network Clock Sync

PLEASE TAKE NOTE OF THE FOLLOWING:

The Momentum network MUST have ONE mi8 or md16ae that is assigned CHANNEL 1. This as-

signment is used to synchronize all of the device clocks on the network. Without this assignment, the

system clock will not sync and audio ‘clicks’ will be heard.

The mo8me unit includes a control panel with an LED display and two push keys (F1 and F2).

The device can be confi gured through a series of key strokes using F1 and F2. The control panel

will only control the local device and cannot change other units via the network.

Using the Control Panel

F1 - Mode Edit / Decrease Value

F2 - Mode Select / Increase Value

Display

Status Indicator

Power Indicator

Key/LED

Description

F1 Mode Select:

F1 activates the edit mode within a particular function.

F2 Mode Select:

F2 generally selects which function to edit.

Power Indicator:

The power indicator shows that a power source is connected to the

Momentum units. The LED is connected to the digital power source.

All other power sources in the system can be monitored via the PC

software.

Status Indicator:

The status indicator is a bi-color LED. GREEN indicates all Momen-

tum Network connections have been found and the network is run-

ning. RED indicates there are one of two problems;

1) An Ethernet link is not established or is not connected.

2) The audio sync packet (channel 1) is not found.