All plumbing work should be carried
out by a suitably qualified and
competent person, in accordance
with all applicable local and national
regulations.

The water quality must conform to
country requirements for drinking
water.

– The appliance is only suitable for

connection to the cold water supply.

– The water pressure must be between

25 and 120 psi (1.72-8.25 bar).

– A separate shut-off valve must be

installed, so that the water supply
can be interrupted as needed.

– The maximum outer diameter of the

water pipe (without fittings):

3

/

8

" (10 mm).

The shut-off valve for the water
connection must not be located
behind the appliance. It is
recommended to place the shut-off
valve directly next to the appliance
(base unit) or in another easily
accessible location.