Installation instructions – Marquis Spas User Manual

Page 12

Advertising
background image

INSTALLATION
INSTRUCTIONS

ELECTRICAL REQUIREMENTS

It is the responsibility of the spa owner to ensure
that all electrical connections are made in accor-
dance with all electric codes in effect at the time of
installation.

240 Volt:

All connections must be made in accordance with
the wiring diagram found on the inside of the
control box cover. Connections should be made
with copper conductors only – aluminum wiring
should not be used with this system. All conductors,
circuit breakers, and/or fuses must be sized in
accordance to the Total Amperage Load as
specified:

• Permanently connected
• Rated 240V, 60Hz, 50A, three wires plus

ground (6 AWG copper)

• Fuse or circuit breaker size: 50 amp

This equipment is designed to operate on 60Hz Alternating Current only at a voltage
of 240. Units to be operated at 240V must have all connections made by a qualified
electrician in accordance with any electric codes in effect at the time of installation. All
240V units require a three wire plus ground (line 1, line 2, neutral, ground). Refer to
the label at the terminal block.

A pressure wire connector is located on the exterior of the control box. If the
installation includes a common bonding grid (reinforced concrete slab, ground plate
beneath the spa, or any metal water pipe connection), this pressure wire connector
should be bonded, with at least #8 AWG (8.42mm

2

, #6 in Canada) copper wire, to

any metal ladder, water pipe, or other metal, within five feet of the spa.

120 Volt:

120V units must only be connected to a properly
grounded, grounding type15 amp receptacle. 120V
equipment is designed to operate on 60Hz
Alternating current only at a voltage of 120, 12.5
amp. maximum load.

To Convert 120V to 240V

All connections must be made by a licensed
electrician.

1. Disconnect from power and remove cord.
2. Move red wire (TB-1) to (TB-4) as indicated by

gray area.

3. Move the Heater Mode selector (J23) on the

Control Board from (20A) to (50A) position.
Ground Fault Circuit Interrupters (GFCI),
#8145, are available from your Dealer.

(CONTINUED)